Toll Free 1.866.636.2487

Glass Fiber Filter with Binder, AP20, 47mm AP2004700 EMD Millipore

Our Price:
91.95
Category
Manufacturer
SKU
AP2004700
Industrial & Scientific has plenty of hardship to offer when it comes to safeguard analytical process control, and controlled environments. Glass Fiber Filter with Binder, AP20, 47mm offers new ingenious resolution to your burden, take a walk on the safe side. EMD Millipore will not compromise on accuracy and quality, identify their perfect solutions points by yourself. Find the right low-priced instruments and have lean on plans for research and development.
Millipore filters with binder resin have superior wet strength and are e x cellent for qualitative analysis and prefiltration, especially for heavily contaminated liquids. They are also widely used for clarification of aqueous solutions.
Type AP15
  • Lowest dirt-holding capacity
  • Recommended prefilter for 0.2 to 0.6 µm filters

Type AP20
  • Lower retention, higher dirt-holding capacity than AP15 filters
  • Recommended prefilter for 0.8 to 8.0 µm filters
  • Use upstream to protect type AP15 filters

Type AP25
  • Added thickness yields same retention and greater dirt-holding capacity as AP20
  • Recommended prefilter for 0.9 to 8 µm filters, especially for proteinaceous and heavily contaminated liquids
  • Use upstream to protect type AP15 filters

Glass Fiber Filter with Binder, AP20, 47mm
This listing is for Pack of 100
Description Glass Fiber Filter with binder
Background Information Overview
Millipore fibrous disc filters are available in a wide range of flow rates and throughput capacities. Our Glass Fiber filters are available with or without binder resins and can be sterilized by EO, gamma, or autoclave (121 °C at 1 bar).
Glass Fiber Filters with Binder Resin:
Millipore filters with binder resin have superior wet strength and are excellent for qualitative analysis and prefiltration, especially for heavily contaminated liquids. They are also widely used for clarification of aqueous solutions.
Type AP15
•Lowest dirt-holding capacity
•Recommended prefilter for 0.2 to 0.6 µm filters
Type AP20
•Lower retention, higher dirt-holding capacity than AP15 filters
•Recommended prefilter for 0.8 to 8.0 µm filters
•Use upstream to protect type AP15 filters
Type AP25
•Added thickness yields same retention and greater dirt-holding capacity as AP20
•Recommended prefilter for 0.9 to 8 µm filters, especially for proteinaceous and heavily contaminated liquids
•Use upstream to protect type AP15 filters
Glass Fiber Filters without Binder Resin:
The filters without binder resin retain their structural integrity without weight loss when heated up to 500 °C and can therefore be used in gravimetric analysis as well as for the filtration of hot gases.
Type APFA
•Retains fine particles with good efficiency, even at high flow rates
•Recommended for monitoring wastewater and collecting suspended particles in gases (e.g., fumes from chimneys)
•Use in biochemical applications (e.g., collection of cells and filtration of protein or nucleic acid precipitates)
Type APFB
•Higher mechanical strength when wet and greater loading capacity than type APFA filters
•Use for liquid clarification, quantification of solids in suspensions of fine particles, and scintillation counting
Type APFC
•Greater retention, especially for fine particulate and microorganism removal than type APFA filters
•Use for determining total suspended solids in drinking water
•Use for filtering proteins or nucleic acid TCA precipitates and for collecting cells and microorganisms
Type APFD
•Thick filter with high flow and low retention
•Use for clarifying suspensions containing particulates greater than 1.0 µm
Type APFF
•Use for filtering extremely fine precipitates such as protein, nucleic acids, or serum precipitates
•Recommended for USEPA method 1311 for TCLP analysis
Type AP40
•Recommended for Standard Methods Total Suspended Solids 2540D
•Recommended for USEPA method 1311 for TCLP analysis
•Maintains structural integrity without weight loss when ignited to 550 °C (1022 °F) after sample filtration
•Recommended for determining volatile suspended matter in wastewater and industrial effluents Filter Code AP20
Filter Color White
Maximum Operating Temperature 100 °C
Filter Type Depth filter Application This is a 47 mm hydrophilic Glass Fiber with Binder Resin filter with a 2.0 um ( 2 micron ) filter pore size. The 2 micron hydrophilic glass fiber filter is a recommended prefilter for 0.9 to 8um filters, especially for proteinaceious & heavily contaminated liquids. Wettability Hydrophilic Pore Size 2.0 µm
Porosity % 90%
Water Flow Rate
  • 1.3 mL/min x cm²
Filter Surface Plain
Thickness 380 µm
Filter Diameter () 47 mm Chemistry
  • Glass Fiber with Binder Resin
Material Size 100 pack, AP20, 47 mm
From time to time treat yourself to a piece to cover your demands. The product to meet your needs is available for less, so save money on an affordable item, courtesy of shopping at Neobits. The Neobits platform features a wide variety of inexpensive products, for a lower price. Here you can find unparalleled items. Find a huge variety of similar well designed products bellow. If you have any questions, don't hesitate to contact our Customer Service department, after all, they are here for you. For a large variety and more related items, please visit other sub-categories for anything you need.